8C0K
fragment-linked stabilizer for ERa - 14-3-3 interaction (1075302)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-10-12 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97625 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 81.839, 112.255, 62.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 66.130 - 1.400 |
R-factor | 0.1746 |
Rwork | 0.174 |
R-free | 0.18410 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.195 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | MOLREP |
Refinement software | PHENIX (1.19.2-4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 66.130 | 1.420 |
High resolution limit [Å] | 1.400 | 1.400 |
Number of reflections | 53382 | 2833 |
<I/σ(I)> | 15.1 | |
Completeness [%] | 93.3 | |
Redundancy | 12.7 | |
CC(1/2) | 0.998 | 0.767 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M HEPES (pH 7.1), PEG400 (24% (v/v)), 0.19 M CaCl2 and 5% (v/v) Glycerol |