8BYW
Rut B structure
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06DA |
| Synchrotron site | SLS |
| Beamline | X06DA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-03-15 |
| Detector | DECTRIS PILATUS 300K |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 1 |
| Unit cell lengths | 69.562, 108.252, 123.744 |
| Unit cell angles | 85.74, 83.33, 74.27 |
Refinement procedure
| Resolution | 48.710 - 1.590 |
| R-factor | 0.2075 |
| Rwork | 0.206 |
| R-free | 0.23290 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.852 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.18rc2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.710 | 1.647 |
| High resolution limit [Å] | 1.590 | 1.590 |
| Number of reflections | 447821 | 43730 |
| <I/σ(I)> | 7.55 | |
| Completeness [%] | 96.5 | |
| Redundancy | 3.5 | |
| CC(1/2) | 0.995 | 0.481 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | PEG |