8BYE
fragment-linked stabilizer for ERa - 14-3-3 interaction (1075313)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE MASSIF-1 |
Synchrotron site | ESRF |
Beamline | MASSIF-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-11-27 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.96546 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 81.772, 111.967, 62.371 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.340 - 1.600 |
R-factor | 0.1746 |
Rwork | 0.174 |
R-free | 0.20660 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.136 |
Data reduction software | DIALS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX (1.19.2-4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.340 | 1.630 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 153207 | 1826 |
<I/σ(I)> | 9.7 | |
Completeness [%] | 99.4 | |
Redundancy | 4 | |
CC(1/2) | 0.991 | 0.674 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M HEPES (pH 7.3), PEG400 (28% (v/v)), 0.19 M CaCl2 and 5% (v/v) Glycerol |