Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I24 |
| Synchrotron site | Diamond |
| Beamline | I24 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-02-03 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9795 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 60.937, 81.594, 95.785 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 62.113 - 1.700 |
| Rwork | 0.199 |
| R-free | 0.23010 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 8bbz |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.583 |
| Data reduction software | autoPROC |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 62.113 | 1.761 |
| High resolution limit [Å] | 1.700 | 1.700 |
| Number of reflections | 53238 | 5226 |
| <I/σ(I)> | 12.8 | 0.7 |
| Completeness [%] | 100.0 | |
| Redundancy | 13.4 | |
| CC(1/2) | 0.998 | 0.328 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | (0.2 M LiSO4, 0.1 M Bis Tris pH 6.5, 25% w/v PEG 3350 |