8B2O
Millisecond cryo-trapping by the spitrobot crystal plunger, CTX-M-14 E166A, Ampicillin, 5 sec
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, EMBL c/o DESY BEAMLINE P14 (MX2) |
Synchrotron site | PETRA III, EMBL c/o DESY |
Beamline | P14 (MX2) |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-02-22 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.97626 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 41.812, 41.812, 232.962 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 77.650 - 1.860 |
R-factor | 0.2142 |
Rwork | 0.212 |
R-free | 0.25350 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6gth |
RMSD bond length | 0.002 |
RMSD bond angle | 0.545 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 77.654 | 2.094 |
High resolution limit [Å] | 1.856 | 1.856 |
Number of reflections | 200593 | 10125 |
<I/σ(I)> | 8.8 | |
Completeness [%] | 0.8 | 37.2 |
Redundancy | 15.3 | |
CC(1/2) | 0.998 | 0.718 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 4.5 | 293 | 40% PEG8000, 200 mM LiSO4, 100 mM NaOAc, pH 4.5 |