8AR5
Small molecular stabilizer for ERalpha and 14-3-3 (1080265)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, DESY BEAMLINE P11 |
| Synchrotron site | PETRA III, DESY |
| Beamline | P11 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-08-26 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.033200 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 82.140, 112.354, 62.410 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 41.790 - 1.400 |
| R-factor | 0.1376 |
| Rwork | 0.136 |
| R-free | 0.16225 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4jc3 |
| RMSD bond length | 0.013 |
| RMSD bond angle | 1.603 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.790 | 1.430 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Number of reflections | 56728 | 2804 |
| <I/σ(I)> | 41.6 | |
| Completeness [%] | 99.8 | |
| Redundancy | 13.1 | |
| CC(1/2) | 0.999 | 0.996 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M HEPES (pH 7.1), PEG400 (24% (v/v)), 0.19 M CaCl2 and 5% (v/v) Glycerol |