Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2021-11-27
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9763
Spacegroup nameP 41 21 2
Unit cell lengths109.315, 109.315, 135.866
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution85.170 - 2.271
Rwork0.177
R-free0.23760
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3beo
RMSD bond length0.012
RMSD bond angle1.639
Data reduction softwareXDS (Feb 5, 2021)
Data scaling softwareAimless (V0.7.7)
Phasing softwareREFMAC (5)
Refinement softwareREFMAC (5.8.0352)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]85.1702.353
High resolution limit [Å]2.2712.271
Rmerge0.2013.536
Number of reflections365871828
<I/σ(I)>14.61.2
Completeness [%]95.752.8
Redundancy26.827.7
CC(1/2)0.9990.590
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.62920.2 M Ammonium sulfate 50 mM BIS-TRIS pH 5.6 28% PEG 3350

219869