8A83
rsEGFP2 with a chlorinated chromophore in the fluorescent ON-state in a crystal dehydrated after illumination
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL7-1 |
Synchrotron site | SSRL |
Beamline | BL7-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-06-26 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.19 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 51.484, 58.980, 64.484 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.786 - 1.810 |
R-factor | 0.2013 |
Rwork | 0.200 |
R-free | 0.22900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5dty |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.790 | 1.875 |
High resolution limit [Å] | 1.810 | 1.810 |
Number of reflections | 18434 | 1806 |
<I/σ(I)> | 16.16 | |
Completeness [%] | 99.5 | |
Redundancy | 2 | |
CC(1/2) | 1.000 | 0.794 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 1.76 M ammonium sulfate, 0.1 M HEPES; Cryoprotectant 1.6 M sucrose, 2.72 M ammonium sulfate, 0.16 M HEPES |