8A74

PcIDS1_F315A in complex with Mg2+ and GPP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2020-02-16
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths59.210, 78.250, 89.260
Unit cell angles90.00, 101.84, 90.00
Refinement procedure
Resolution15.000 - 1.900
R-factor0.2017
Rwork0.200
R-free0.24150
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8a6u
RMSD bond length0.002
RMSD bond angle1.173
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.000
High resolution limit [Å]1.9001.900
Rmerge0.0940.538
Number of reflections618438868
<I/σ(I)>6.92.4
Completeness [%]98.399.4
Redundancy3.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.52930.1 M MES, 0.2 M MgCl2, 25% PEG 4000

219869