7ZXL

H93A Mutant of Recombinant CODH-II

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-10-06
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths112.330, 75.175, 71.354
Unit cell angles90.00, 111.30, 90.00
Refinement procedure
Resolution26.164 - 1.200
R-factor0.114
Rwork0.113
R-free0.13780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3b51
RMSD bond length0.011
RMSD bond angle1.464
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.8801.240
High resolution limit [Å]1.2001.200
Rmerge0.0570.653
Rmeas0.0670.812
Number of reflections16554213229
<I/σ(I)>12.81.6
Completeness [%]96.1
Redundancy3.6
CC(1/2)0.9990.636
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5291.150.1M Bis-Tris pH 6.5, PEG 3350 10-18%, Ammonium sulphate 0.18M