Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04-1 |
| Synchrotron site | Diamond |
| Beamline | I04-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-09-25 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.953970 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 38.005, 43.206, 79.348 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.670 - 1.140 |
| Rwork | 0.196 |
| R-free | 0.20980 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5lrq |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.972 |
| Data reduction software | xia2 |
| Data scaling software | Aimless (0.7.4) |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 39.670 | 39.670 | 1.160 |
| High resolution limit [Å] | 1.140 | 6.140 | 1.140 |
| Rmerge | 0.080 | 0.048 | 1.287 |
| Rmeas | 0.094 | 0.056 | 1.650 |
| Rpim | 0.049 | 0.028 | 1.015 |
| Number of reflections | 48392 | 383 | 2393 |
| <I/σ(I)> | 9.8 | ||
| Completeness [%] | 99.8 | ||
| Redundancy | 6.4 | 5.9 | 4 |
| CC(1/2) | 0.998 | 0.998 | 0.329 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 293 | 0.1 M Buffer system 3 (1 M Tris, 1 M BICINE, pH 8.5), 34-44% Precipitant Solution 3 (20% PEG 4000, 40%) and 60-80 mM Halogens Mix (NaF, NaBr and NaI) solution |