7YZM
MgADPNP-bound DCCP:DCCP-R complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-02-03 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.91841 |
Spacegroup name | P 1 |
Unit cell lengths | 78.120, 81.673, 121.377 |
Unit cell angles | 100.61, 97.13, 90.00 |
Refinement procedure
Resolution | 26.720 - 1.820 |
R-factor | 0.1638 |
Rwork | 0.164 |
R-free | 0.20130 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6ENO.pdb |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.260 | 1.880 |
High resolution limit [Å] | 1.820 | 1.820 |
Rmerge | 0.124 | |
Number of reflections | 257334 | 24967 |
<I/σ(I)> | 9.7 | |
Completeness [%] | 97.7 | |
Redundancy | 5.48 | |
CC(1/2) | 0.996 | 0.712 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291.15 | ammonium sulfate, TrisHCl pH 8.0,PEG 4000 |