Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7YZM

MgADPNP-bound DCCP:DCCP-R complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-02-03
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameP 1
Unit cell lengths78.120, 81.673, 121.377
Unit cell angles100.61, 97.13, 90.00
Refinement procedure
Resolution26.720 - 1.820
R-factor0.1638
Rwork0.164
R-free0.20130
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ENO.pdb
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.2601.880
High resolution limit [Å]1.8201.820
Rmerge0.124
Number of reflections25733424967
<I/σ(I)>9.7
Completeness [%]97.7
Redundancy5.48
CC(1/2)0.9960.712
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP291.15ammonium sulfate, TrisHCl pH 8.0,PEG 4000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon