7YYL

nucleotide-free DCCP:DCCP-R complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2020-02-10
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameP 1
Unit cell lengths81.672, 83.332, 124.376
Unit cell angles99.72, 95.62, 94.02
Refinement procedure
Resolution46.930 - 3.250
R-factor0.2486
Rwork0.246
R-free0.30270
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ENO.pdb
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.9303.370
High resolution limit [Å]3.2503.250
Rmerge0.138
Number of reflections452164476
<I/σ(I)>4.6
Completeness [%]90.0
Redundancy1.95
CC(1/2)0.9790.451
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP291.150.2 M ammonium sulfate, 0.1 M Tris-HCl pH 8.0 and 10% (w/v) PEG 8000