Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7XEN

SufS with L-penicillamine

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL44XU
Synchrotron siteSPring-8
BeamlineBL44XU
Temperature [K]100
Detector technologyPIXEL
Collection date2020-07-20
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.900
Spacegroup nameP 31 2 1
Unit cell lengths94.200, 94.200, 133.200
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.100 - 2.470
R-factor0.1639
Rwork0.161
R-free0.21120
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5zs9
RMSD bond length0.012
RMSD bond angle2.309
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]47.10047.1002.570
High resolution limit [Å]2.47010.0002.470
Rmerge0.0550.0330.729
Rmeas0.0590.0350.782
Total number of observations180175
Number of reflections246894082771
<I/σ(I)>16.3335.692.12
Completeness [%]98.392.399.5
Redundancy7.2987.1087.716
CC(1/2)0.9990.9990.782
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72930.1 M Tris-HCl, 50 mM Lithium sulfate, 50% (v/v) PEG200