7XA1
Thermotoga maritima ferritin variant-Tm-E(S111Y)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-01-02 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.276911 |
| Spacegroup name | P 32 1 2 |
| Unit cell lengths | 56.609, 56.609, 128.087 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 27.640 - 2.200 |
| R-factor | 0.2312 |
| Rwork | 0.226 |
| R-free | 0.27940 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1vlg |
| Data reduction software | HKL-3000 |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 27.640 | 2.280 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 12639 | 649 |
| <I/σ(I)> | 7.44 | |
| Completeness [%] | 91.5 | |
| Redundancy | 1.1 | |
| CC(1/2) | 1.000 | 1.000 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 25mM HEPES pH 7.5, 35% 1,4-dioxane |