7XA0
Thermotoga maritima ferritin variant-Tm-E(S111F)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-01-02 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.97915 |
Spacegroup name | P 32 1 2 |
Unit cell lengths | 55.337, 55.337, 128.818 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 42.940 - 2.030 |
R-factor | 0.2076 |
Rwork | 0.203 |
R-free | 0.24530 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1vlg |
Data reduction software | autoPROC |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.940 | 2.103 |
High resolution limit [Å] | 2.030 | 2.030 |
Number of reflections | 15978 | 1498 |
<I/σ(I)> | 21.51 | |
Completeness [%] | 98.7 | |
Redundancy | 1.1 | |
CC(1/2) | 1.000 | 1.000 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100mM MES pH 6.0, 200mM Lithium sulfate, 35% MPD |