7X70
TRIM7 in complex with C-terminal peptide of NSP8
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-03-06 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.979 |
Spacegroup name | P 65 |
Unit cell lengths | 80.100, 80.100, 53.127 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 26.220 - 1.250 |
R-factor | 0.1433 |
Rwork | 0.142 |
R-free | 0.17030 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 7w0q |
RMSD bond length | 0.009 |
RMSD bond angle | 1.120 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHENIX |
Refinement software | PHENIX (1.20_4459) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 26.220 | 1.295 |
High resolution limit [Å] | 1.250 | 1.250 |
Number of reflections | 46056 | 2099 |
<I/σ(I)> | 15.96 | |
Completeness [%] | 85.9 | |
Redundancy | 2 | |
CC(1/2) | 0.999 | 0.732 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | LIQUID DIFFUSION | 291.15 | Potassium sodium tartrate, Lithium sulfate, Tris-HCl |