7WQU
FeoC from Klebsiella pneumoniae
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL13B1 |
Synchrotron site | NSRRC |
Beamline | BL13B1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-05-12 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0 |
Spacegroup name | I 2 3 |
Unit cell lengths | 176.292, 176.292, 176.292 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.382 - 4.202 |
R-factor | 0.2205 |
Rwork | 0.219 |
R-free | 0.23230 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4awx |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 4.390 |
High resolution limit [Å] | 4.200 | 4.200 |
Number of reflections | 6774 | 845 |
<I/σ(I)> | 2 | |
Completeness [%] | 100.0 | |
Redundancy | 12 | |
CC(1/2) | 0.980 | 0.952 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 2 M ammonium sulfate and 0.1 M sodium acetate trihydrate pH 4.5 |