7WOH
SARS-CoV-2 3CLpro
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-05-15 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.97915 |
| Spacegroup name | P 1 |
| Unit cell lengths | 51.791, 63.174, 63.184 |
| Unit cell angles | 78.52, 71.48, 71.52 |
Refinement procedure
| Resolution | 19.850 - 1.720 |
| R-factor | 0.2003 |
| Rwork | 0.199 |
| R-free | 0.21570 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6lu7 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.048 |
| Data scaling software | HKL-3000 |
| Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.630 |
| High resolution limit [Å] | 1.600 | 1.600 |
| Number of reflections | 68642 | 2077 |
| <I/σ(I)> | 40.6 | |
| Completeness [%] | 97.0 | |
| Redundancy | 6.4 | |
| CC(1/2) | 0.995 | 0.954 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6 | 290 | 100 mM MES (pH 6.0), 3% DMSO, 1 mM DTT, 6% polyethylene glycol (PEG) 6000 |