Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7WO3

SARS-CoV-2 3CLpro

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL19U1
Synchrotron siteSSRF
BeamlineBL19U1
Temperature [K]100
Detector technologyPIXEL
Collection date2021-05-15
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97915
Spacegroup nameP 21 21 2
Unit cell lengths45.249, 62.892, 104.992
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.450 - 2.010
R-factor0.199
Rwork0.197
R-free0.24300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6lu7
RMSD bond length0.007
RMSD bond angle1.128
Data reduction softwareHKL-3000
Refinement softwarePHENIX (1.20-4459)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.030
High resolution limit [Å]2.0002.000
Number of reflections20375947
<I/σ(I)>10.4
Completeness [%]98.3
Redundancy7.4
CC(1/2)0.9910.476
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP290100 mM MES (pH 6.0), 3% DMSO, 1 mM DTT and 6% polyethylene glycol (PEG) 6000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon