7VZT
A human neutralizing antibody targeting SARS-CoV-2 RBD
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-07-17 |
| Detector | DECTRIS PILATUS 2M |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 150.605, 150.605, 121.320 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 49.400 |
| High resolution limit [Å] | 3.400 | 3.410 |
| Number of reflections | 15881 | 15881 |
| <I/σ(I)> | 12.6 | |
| Completeness [%] | 71.9 | |
| Redundancy | 34.7 | |
| CC(1/2) | 0.997 | 0.997 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291 | 100mM HEPES (pH 7.5), 40% (v/v) Polyethylene glycol monomethyl ether 400 |