7VZT
A human neutralizing antibody targeting SARS-CoV-2 RBD
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-07-17 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.979 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 150.605, 150.605, 121.320 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 49.400 |
High resolution limit [Å] | 3.400 | 3.410 |
Number of reflections | 15881 | 15881 |
<I/σ(I)> | 12.6 | |
Completeness [%] | 71.9 | |
Redundancy | 34.7 | |
CC(1/2) | 0.997 | 0.997 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 100mM HEPES (pH 7.5), 40% (v/v) Polyethylene glycol monomethyl ether 400 |