Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-17A |
| Synchrotron site | Photon Factory |
| Beamline | BL-17A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-02-20 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.980000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 127.740, 128.870, 231.570 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.128 - 3.818 |
| R-factor | 0.2281 |
| Rwork | 0.226 |
| R-free | 0.26710 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3vr5 |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.509 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER (2.5.6) |
| Refinement software | PHENIX (1.12-2829) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 46.128 | 46.128 | 4.050 |
| High resolution limit [Å] | 3.818 | 11.190 | 3.818 |
| Rmerge | 0.172 | 0.036 | 0.953 |
| Rmeas | 0.199 | 0.042 | 1.105 |
| Number of reflections | 71426 | 2797 | 11449 |
| <I/σ(I)> | 7.61 | 31.43 | 1.54 |
| Completeness [%] | 99.5 | 97.9 | 99 |
| Redundancy | 3.904 | 3.706 | 3.881 |
| CC(1/2) | 0.993 | 0.998 | 0.592 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 296 | Bis Tris propane, NaF, PEG-3350 |