Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL13C1 |
Synchrotron site | NSRRC |
Beamline | BL13C1 |
Temperature [K] | 298 |
Detector technology | CCD |
Collection date | 2017-12-16 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.975 |
Spacegroup name | P 31 |
Unit cell lengths | 60.277, 60.277, 131.385 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 27.801 - 2.319 |
R-factor | 0.1985 |
Rwork | 0.196 |
R-free | 0.24970 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5yuo |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.400 |
High resolution limit [Å] | 2.319 | 2.319 |
Rmerge | 0.064 | 0.509 |
Number of reflections | 23123 | 2309 |
<I/σ(I)> | 18.1 | 2.4 |
Completeness [%] | 99.9 | 99.9 |
Redundancy | 3.2 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 25% PEG 4000, 100mM MES Sodium Salt pH 6.5, 200mM Magnesium Chloride |