7VQV
de novo design based on 1r26
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-09-19 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9875 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 41.516, 50.458, 64.699 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 32.370 - 1.530 |
| R-factor | 0.1887 |
| Rwork | 0.187 |
| R-free | 0.22500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1r26 |
| RMSD bond length | 0.017 |
| RMSD bond angle | 1.854 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.560 |
| High resolution limit [Å] | 1.530 | 1.530 |
| Number of reflections | 20876 | 982 |
| <I/σ(I)> | 38.271 | |
| Completeness [%] | 99.9 | |
| Redundancy | 12.2 | |
| CC(1/2) | 0.996 | 0.899 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | 1,4-Dioxane, bicine, PEG 20000 |