7V10
Factor XIa in Complex with Compound 2d
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-08-29 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.540 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.411, 59.693, 67.154 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.615 - 1.798 |
R-factor | 0.1942 |
Rwork | 0.190 |
R-free | 0.23000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3sos |
RMSD bond length | 0.007 |
RMSD bond angle | 0.933 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHENIX (1.10) |
Refinement software | PHENIX (1.10) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.830 |
High resolution limit [Å] | 1.798 | 4.880 | 1.798 |
Rmerge | 0.140 | 0.082 | 0.990 |
Rmeas | 0.161 | 0.093 | 1.185 |
Rpim | 0.076 | 0.042 | 0.642 |
Number of reflections | 20090 | 1246 | 794 |
<I/σ(I)> | 7.3 | ||
Completeness [%] | 88.0 | 98.2 | 71.6 |
Redundancy | 4 | 4.7 | 3.2 |
CC(1/2) | 0.993 | 0.524 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5 | 293 | 24% PEG 4000, 100mM Na Citrate pH 5.0 |