7UUG
SARS-CoV-2 Main Protease S144A (Mpro S144A) in Complex with ML1006a
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL12-2 |
| Synchrotron site | SSRL |
| Beamline | BL12-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-03-08 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97946 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 63.613, 45.462, 104.749 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.940 - 2.000 |
| R-factor | 0.1853 |
| Rwork | 0.182 |
| R-free | 0.24040 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6lze |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.591 |
| Data reduction software | XDS |
| Data scaling software | SCALA (3.3.22) |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 104.749 | 34.916 | 2.110 |
| High resolution limit [Å] | 2.000 | 6.320 | 2.000 |
| Rmerge | 0.026 | 1.269 | |
| Rmeas | 0.067 | 0.029 | 1.374 |
| Rpim | 0.026 | 0.012 | 0.521 |
| Total number of observations | 142206 | 4427 | 20933 |
| Number of reflections | 21242 | 764 | 3047 |
| <I/σ(I)> | 13.2 | 40.3 | 1.5 |
| Completeness [%] | 99.9 | 99.4 | 100 |
| Redundancy | 6.7 | 5.8 | 6.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 289.15 | Sitting drops consisted of 0.19 uL A:0.19 uL B: A) 5.1 mg/mL Mpro S144A + 0.9 mM ML1006a in in 20 mM Tris pH 7.3 + 3 mM TCEP + 3 % DMSO B) 0.1 M MES pH 6.5, 10% PEG20000 |