7UG1
CDK2 liganded with para chloro ANS
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 93 |
Detector technology | CCD |
Collection date | 2012-09-28 |
Detector | RIGAKU SATURN 944+ |
Wavelength(s) | 1.54178 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.180, 69.120, 72.200 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.420 - 1.840 |
R-factor | 0.185 |
Rwork | 0.182 |
R-free | 0.24220 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ez7 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.420 | 1.890 |
High resolution limit [Å] | 1.840 | 1.840 |
Rmeas | 0.065 | 0.746 |
Number of reflections | 22931 | 1416 |
<I/σ(I)> | 27.8 | 2.7 |
Completeness [%] | 96.6 | 81.8 |
Redundancy | 7 | |
CC(1/2) | 1.000 | 0.808 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | 50 mM sodium/potassium phosphate, pH 7.5, 50 mM HEPES, pH 7.5, 5% v/v PEG3350 |