7UCY

Integrin alaphIIBbeta3 complex with gantofiban

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2014-08-25
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.963
Spacegroup nameP 21 21 2
Unit cell lengths258.550, 144.460, 105.100
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.980 - 2.350
R-factor0.221398991762
Rwork0.221
R-free0.23081
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3t3p
RMSD bond length0.007
RMSD bond angle0.576
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.410
High resolution limit [Å]2.3502.350
Number of reflections31583923370
<I/σ(I)>3.78
Completeness [%]99.7
Redundancy2.14
CC(1/2)0.9760.111
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.927711% PEG 8000, 0.2 M ammonium sulfate, 0.1 M Tris-HCl, pH 8.9

219869