7U9W
Pfs230 D1 domain in complex with 230AS-88
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-03-11 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 107.800, 129.820, 73.550 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.560 - 2.790 |
| R-factor | 0.2256 |
| Rwork | 0.224 |
| R-free | 0.25500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 7jum |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.539 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.560 | 2.870 |
| High resolution limit [Å] | 2.790 | 2.790 |
| Number of reflections | 13052 | 936 |
| <I/σ(I)> | 15.08 | |
| Completeness [%] | 99.2 | |
| Redundancy | 7.2 | |
| CC(1/2) | 0.990 | 0.900 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.1 M MES, pH 6.0, 1.0 M lithium chloride, 10% PEG 6000 |