Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7U3F

GID4 in complex with compound 4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2020-03-01
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths40.340, 57.280, 72.530
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.952 - 2.300
R-factor0.2349
Rwork0.233
R-free0.26180
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ccr
Data reduction softwareXDS (20190806)
Data scaling softwareXSCALE (20190806)
Phasing softwarePHASER (2.8.3)
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]44.95244.9522.430
High resolution limit [Å]2.3006.8102.300
Rmerge0.0810.0420.757
Rmeas0.0890.0470.887
Total number of observations45787
Number of reflections77973461119
<I/σ(I)>13.5433.461.52
Completeness [%]98.299.489.5
Redundancy5.8725.4083.601
CC(1/2)0.9980.9980.764
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.529315% PEG5000 MME, 0.1 M Bis-tris

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon