7U04

IOMA class antibody ACS101

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]100
Detector technologyPIXEL
Collection date2021-04-24
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.97741
Spacegroup nameP 32 2 1
Unit cell lengths67.130, 67.130, 199.293
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution43.750 - 2.310
R-factor0.2189
Rwork0.217
R-free0.25620
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6d2p
RMSD bond length0.002
RMSD bond angle0.577
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.7502.340
High resolution limit [Å]2.3102.310
Rmerge0.1291.220
Rmeas0.1361.320
Rpim0.0430.490
Number of reflections237881113
<I/σ(I)>19.31.5
Completeness [%]100.0100
Redundancy107.1
CC(1/2)0.8800.500
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.1510% (v/v) glycerol, 0.1M of HEPES (pH 7.5), 5% (w/v) polyethylene glycol 3000 and 30% (v/v) polyethylene glycol 400

219869

PDB entries from 2024-05-15