7TYU

TEAD2 bound to Compound 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.2
Synchrotron siteALS
Beamline5.0.2
Temperature [K]100
Detector technologyCCD
Collection date2018-10-10
DetectorADSC QUANTUM 315
Wavelength(s)1.00
Spacegroup nameC 1 2 1
Unit cell lengths115.270, 61.526, 79.412
Unit cell angles90.00, 111.76, 90.00
Refinement procedure
Resolution33.350 - 1.780
R-factor0.1986
Rwork0.197
R-free0.23020
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5emv
RMSD bond length0.003
RMSD bond angle0.694
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.18rc5_3822)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.8351.986
High resolution limit [Å]1.7801.784
Number of reflections312381536
<I/σ(I)>14
Completeness [%]92.2
Redundancy3.4
CC(1/2)1.0000.783
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.2 M Na/K Tartrate, 0.1 M Bis Tris pH 6.5, 35% PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon