7TTK
Stable-5-LOX
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-03-27 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 55.440, 203.197, 76.566 |
Unit cell angles | 90.00, 110.24, 90.00 |
Refinement procedure
Resolution | 101.600 - 1.980 |
R-factor | 0.1666 |
Rwork | 0.165 |
R-free | 0.20100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3o8y |
RMSD bond length | 0.011 |
RMSD bond angle | 1.084 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 101.600 | 2.050 |
High resolution limit [Å] | 1.980 | 1.980 |
Number of reflections | 107838 | 10149 |
<I/σ(I)> | 9.55 | 1.15 |
Completeness [%] | 98.4 | 92.61 |
Redundancy | 2 | |
CC(1/2) | 0.995 | 0.425 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 295 | 10% Tacsimate |