Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7RYL

T cell receptor CO3

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2020-10-09
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.93222
Spacegroup nameP 21 21 21
Unit cell lengths50.987, 76.414, 113.148
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.470 - 2.000
R-factor0.2011
Rwork0.199
R-free0.24690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4x6b
RMSD bond length0.003
RMSD bond angle0.629
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.4702.050
High resolution limit [Å]2.0002.000
Rpim0.743
Number of reflections306682241
<I/σ(I)>10.3
Completeness [%]100.0
Redundancy6.8
CC(1/2)0.9970.538
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.15M Ammonium sulfate, 15% PEG 4000, 0.1 MES pH 6

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon