Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7RJ0

Mouse Gamma S Crystallin L16 Octamer

Replaces:  6MYH
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-10
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9793
Spacegroup nameP 21 21 2
Unit cell lengths61.095, 77.591, 154.052
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.001 - 2.919
R-factor0.2039
Rwork0.199
R-free0.28970
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1zwo
RMSD bond length0.011
RMSD bond angle1.293
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.950
High resolution limit [Å]2.9002.900
Number of reflections16343800
<I/σ(I)>25
Completeness [%]99.3
Redundancy10
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP52970.15 M sodium acetate, pH 5.0, 22% PEG550 MME, 8% PEG300

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon