CC-Type2-(Ue)4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2021-10-01
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.92
Spacegroup nameP 1 21 1
Unit cell lengths33.946, 57.211, 43.946
Unit cell angles90.00, 96.66, 90.00
Refinement procedure
Resolution43.690 - 1.640
R-factor0.1814
Rwork0.179
R-free0.22650
Structure solution methodSAD
RMSD bond length0.011
RMSD bond angle1.451
Data reduction softwareDIALS
Data scaling softwareAimless
Phasing softwareSHELXDE
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.6901.699
High resolution limit [Å]1.6401.640
Rmerge0.1071.706
Rmeas0.1111.834
Rpim0.0300.649
Number of reflections17660863
<I/σ(I)>13.130.49
Completeness [%]85.942.1
Redundancy12.57.4
CC(1/2)0.9990.456
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP52931.5 mM peptide, 0.1 M Calcium chloride dihydrate 50 mM Sodium acetate, and 10 % w/v PEG 6000, at pH 5.0