Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7QVZ

ARUK3001043_Notum

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2019-04-08
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9795
Spacegroup nameP 21 21 21
Unit cell lengths60.152, 71.546, 78.371
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution52.840 - 1.470
R-factor0.1732
Rwork0.171
R-free0.21710
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uzq
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]78.3701.500
High resolution limit [Å]1.4701.470
Number of reflections582822831
<I/σ(I)>12.4
Completeness [%]100.0
Redundancy13
CC(1/2)1.0000.430
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.22961.5 M Ammonium Sulphate 0.1 M Sodium Citrate, pH4.2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon