7PPY

CARM1 in complex with EML709

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-03-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9785
Spacegroup nameP 21 21 2
Unit cell lengths74.677, 98.823, 206.981
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.060 - 2.420
R-factor0.207
Rwork0.205
R-free0.23530
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5ih3
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.0602.490
High resolution limit [Å]2.4202.420
Rmerge0.1151.223
Rmeas0.1311.441
Rpim0.0620.743
Number of reflections581363623
<I/σ(I)>8.80.9
Completeness [%]98.380
Redundancy4.33.2
CC(1/2)0.9980.441
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP829312% PEG 2000, 100mM NaCl, 100mM TrisHCl pH8