7PNN
mVenus released from fusion protein.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, EMBL c/o DESY BEAMLINE P14 (MX2) |
Synchrotron site | PETRA III, EMBL c/o DESY |
Beamline | P14 (MX2) |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-08-16 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.9763 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 61.064, 91.048, 118.556 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.500 - 1.430 |
R-factor | 0.1619 |
Rwork | 0.162 |
R-free | 0.16890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ndj |
Data reduction software | XDS (BUILT=20210323) |
Data scaling software | XSCALE |
Phasing software | PHASER (2.8.3.) |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 59.280 | 1.520 |
High resolution limit [Å] | 1.430 | 1.430 |
Rmeas | 0.074 | 2.159 |
Number of reflections | 60635 | 9593 |
<I/σ(I)> | 18.81 | 1.52 |
Completeness [%] | 99.0 | 97.8 |
Redundancy | 13.36 | 13.56 |
CC(1/2) | 0.999 | 0.786 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 287 | 200 mM KCl, 20% (w/v) PEG3350 |