7PGE
copper transporter PcoB
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 173 |
Detector technology | PIXEL |
Collection date | 2017-05-26 |
Detector | DECTRIS EIGER R 4M |
Wavelength(s) | 1.0 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 65.489, 75.538, 91.510 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.530 - 2.000 |
R-factor | 0.2221 |
Rwork | 0.221 |
R-free | 0.25310 |
Structure solution method | SAD |
RMSD bond length | 0.008 |
RMSD bond angle | 1.076 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.530 | 2.043 |
High resolution limit [Å] | 1.970 | 1.972 |
Number of reflections | 30731 | 4965 |
<I/σ(I)> | 11.47 | |
Completeness [%] | 99.3 | |
Redundancy | 6.6 | |
CC(1/2) | 0.990 | 0.670 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | PEG4000, NaSCN, sodium acetate |