Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7OOU

NaK C-DI mutant with Li+ and K+

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-11-28
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9184
Spacegroup nameC 2 2 21
Unit cell lengths81.481, 88.413, 49.586
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.210 - 1.800
R-factor0.1779
Rwork0.176
R-free0.20590
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3e86
RMSD bond length0.006
RMSD bond angle0.761
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.19_4092)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.2101.860
High resolution limit [Å]1.8001.800
Rmerge0.117
Rmeas0.127
Rpim0.0490.789
Number of reflections169501671
<I/σ(I)>12.460.99
Completeness [%]99.799.76
Redundancy6.56.5
CC(1/2)0.9990.398
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5293200mM K acetate, 40% MPD (2-Methyl-2,4-pentanediol racemate)

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon