Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-30 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.91587 |
Spacegroup name | I 41 2 2 |
Unit cell lengths | 112.896, 112.896, 101.669 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.700 - 2.300 |
Rwork | 0.193 |
R-free | 0.24000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6tjs |
RMSD bond length | 0.014 |
RMSD bond angle | 1.970 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 35.700 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.971 | |
Number of reflections | 394340 | 1424 |
<I/σ(I)> | 26 | |
Completeness [%] | 100.0 | |
Redundancy | 26 | |
CC(1/2) | 0.069 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | Morpheus screen followed by screening |