7O9S
Hantaan virus Gn in complex with Fab nnHTN-Gn2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-03-13 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 0.9686 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 76.130, 76.900, 174.360 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 76.130 | 76.100 | 2.750 |
High resolution limit [Å] | 2.700 | 7.330 | 2.700 |
Rmeas | 0.084 | 0.039 | 0.759 |
Rpim | 0.023 | 0.011 | 0.206 |
Total number of observations | 377959 | ||
Number of reflections | 28789 | 1599 | 1397 |
<I/σ(I)> | 19.8 | 48.2 | 3.4 |
Completeness [%] | 99.7 | 100 | 99.1 |
Redundancy | 13.1 | 12 | 13.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 295 | 0.1 M sodium cacodylate pH 6.5, 5 % w/v PGA-LM and 20 % w/v PEG 3350 |