Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-09-27 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.969 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 39.869, 70.546, 112.828 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 56.478 - 1.900 |
Rwork | 0.180 |
R-free | 0.21280 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1oht |
RMSD bond length | 0.010 |
RMSD bond angle | 1.597 |
Data reduction software | Aimless (0.7.4) |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 112.830 | 112.830 | 1.940 |
High resolution limit [Å] | 1.900 | 9.110 | 1.900 |
Rmerge | 0.133 | 0.043 | 1.197 |
Rmeas | 0.153 | 0.049 | 1.394 |
Rpim | 0.073 | 0.024 | 0.699 |
Number of reflections | 12942 | 150 | 808 |
<I/σ(I)> | 8.5 | ||
Completeness [%] | 99.8 | ||
Redundancy | 7.9 | 6 | 7.2 |
CC(1/2) | 0.993 | 0.998 | 0.562 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.1M HEPES pH7.0, 30% v/v Jeffamine ED-2003 |