7NDE
Trichoderma parareesei PL7A beta-glucuronan lyase
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | MAX IV BEAMLINE BioMAX |
Synchrotron site | MAX IV |
Beamline | BioMAX |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-02-23 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9763 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 69.589, 69.589, 111.660 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.550 - 1.450 |
R-factor | 0.1556 |
Rwork | 0.155 |
R-free | 0.17380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2cws |
RMSD bond length | 0.008 |
RMSD bond angle | 0.985 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.18) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.550 | 1.500 |
High resolution limit [Å] | 1.450 | 1.450 |
Number of reflections | 49303 | 4791 |
<I/σ(I)> | 22.47 | |
Completeness [%] | 100.0 | |
Redundancy | 26.2 | |
CC(1/2) | 1.000 | 0.440 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 2.4 M disodium malonate pH 7 |