7N1D
SARS-CoV-2 YLQ peptide-specific TCR pYLQ7
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-03-14 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 1.0 |
Spacegroup name | I 4 |
Unit cell lengths | 109.777, 109.777, 99.641 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.812 | 2.434 |
High resolution limit [Å] | 2.350 | 2.350 |
Number of reflections | 24641 | 2476 |
<I/σ(I)> | 12.84 | |
Completeness [%] | 99.9 | |
Redundancy | 7 | |
CC(1/2) | 0.994 | 0.832 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 295 | 1.2M Potassium sodium tartrate tetrahydrate, 0.1M Tris-base/ Hydrochloric acid (pH 8.0) |