Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7MY6

Se-CrtE C-term His-tag with IPP added

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2020-03-21
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 1 21 1
Unit cell lengths45.423, 144.627, 48.066
Unit cell angles90.00, 95.25, 90.00
Refinement procedure
Resolution45.482 - 2.020
Rwork0.180
R-free0.20880
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7mxz
RMSD bond length0.008
RMSD bond angle1.407
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.2101.990
High resolution limit [Å]1.9401.940
Rmerge0.3452.327
Rpim0.1130.781
Number of reflections455793076
<I/σ(I)>5.71.1
Completeness [%]99.9
Redundancy109.7
CC(1/2)0.9860.392
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP9.5293200 nL of protein at 10 mg/mL was added to 200 nL of reservoir consisting of 90 mM CHES pH 9.5, 180 mM magnesium sulfate, 100 mM trisodium citrate, 22.5% (w/v) PEG 1500

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon