7MLX
SARS-CoV-2 programmed -1 frameshifting element three stem H-type pseudoknot
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2020-11-04 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.979180 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 76.833, 143.240, 133.641 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 71.620 - 2.090 |
R-factor | 0.2008 |
Rwork | 0.199 |
R-free | 0.23090 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | Antibody Fragment model |
RMSD bond length | 0.007 |
RMSD bond angle | 0.943 |
Data reduction software | MOSFLM |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 71.620 | 2.165 |
High resolution limit [Å] | 2.090 | 2.090 |
Number of reflections | 44027 | 4321 |
<I/σ(I)> | 15.98 | |
Completeness [%] | 99.7 | 99.93 |
Redundancy | 6.8 | |
CC(1/2) | 0.999 | 0.803 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 2 % v/v tacsimate pH 4, 0.1 M sodium acetate trihydrate pH 4.6, 16 % w/v polyethylene glycol 3350 |