Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7LNC

X-ray radiation damage series on Thaumatin at 277K, multi-conformer model, dataset 3 (merged)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]277
Detector technologyPIXEL
Collection date2018-11-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.88557
Spacegroup nameP 41 21 2
Unit cell lengths58.824, 58.824, 151.163
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.270 - 1.220
R-factor0.1365
Rwork0.136
R-free0.14700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7lfg
RMSD bond length0.006
RMSD bond angle0.921
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.2701.240
High resolution limit [Å]1.2201.220
Rmerge0.206
Rpim0.0191.605
Number of reflections799074009
<I/σ(I)>26.61.2
Completeness [%]100.099.5
Redundancy112100.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.629324% Na K Tartrate (w/v), 15% ethylene glycol (v/v), and 0.1 M BisTris Propane

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon