7L15

Marsupial T cell receptor Spl_118

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2019-07-27
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.95372
Spacegroup nameP 21 21 21
Unit cell lengths56.396, 82.705, 108.439
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.340 - 2.250
R-factor0.1831
Rwork0.181
R-free0.22650
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)unpublished
RMSD bond length0.007
RMSD bond angle0.927
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.3402.320
High resolution limit [Å]2.2502.250
Rpim0.0300.376
Number of reflections248102247
<I/σ(I)>13.82.4
Completeness [%]100.0
Redundancy6.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29420% PEG 3350, 0.2M LiSO4

219869