7L15
Marsupial T cell receptor Spl_118
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-07-27 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.95372 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 56.396, 82.705, 108.439 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.340 - 2.250 |
R-factor | 0.1831 |
Rwork | 0.181 |
R-free | 0.22650 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | unpublished |
RMSD bond length | 0.007 |
RMSD bond angle | 0.927 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.340 | 2.320 |
High resolution limit [Å] | 2.250 | 2.250 |
Rpim | 0.030 | 0.376 |
Number of reflections | 24810 | 2247 |
<I/σ(I)> | 13.8 | 2.4 |
Completeness [%] | 100.0 | |
Redundancy | 6.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 294 | 20% PEG 3350, 0.2M LiSO4 |